  "x402Version": 2,
  "id": 38932,
  "slug": "38932",
  "resource": "https://api.magentlab.com/api/calc/rads",
  "description": "Oh 2012 radiologist's score (RADS) on one 1-cm axial chest CT slice. Four quadrants (not eight). Each quadrant worst finding: normal 0, interstitial 1, ground_glass 2, consolidation 3. Score 0-12; high when score > 8. Caller-assigned findings only; magent does not interpret CT. Not a diagnosis of inhalation injury. Not a bronchoscopy substitute. Not Endorf AIS inhalation grade. Not Yamamura bronchial wall thickness.",
  "type": "http",
  "serviceName": "magent",
  "resourceType": "Agent Service",
  "accepts": [
    {
      "scheme": "exact",
      "network": "eip155:8453",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "amount": "5000",
      "amountUsd": 0.005,
      "maxTimeoutSeconds": 600
    }
  ],
  "outputSchema": {
    "properties": {
      "example": {
        "type": "object"
      },
      "type": {
        "type": "string"
      }
    },
    "required": [
      "type"
    ],
    "type": "object"
  },
  "extensions": {
    "bazaar": {
      "info": {
        "iconUrl": "https://api.magentlab.com/favicon.ico",
        "input": {
          "body": {
            "items": [
              {
                "q1": "normal",
                "q2": "normal",
                "q3": "normal",
                "q4": "normal"
              },
              {
                "q1": "normal",
                "q2": "normal",
                "q3": "normal",
                "q4": "normal"
              }
            ]
          },
          "method": "POST",
          "type": "http"
        },
        "output": {
          "example": {
            "count": 2,
            "items": [
              {
                "citation": {
                  "authors": "Oh JS, Chung KK, Allen A, Batchinsky AI, Huzar T, King BT, et al.",
                  "doi": "10.1097/BCR.0b013e318237455f",
                  "id": "oh-2012",
                  "pmid": "22210063",
                  "source": "J Burn Care Res. 2012;33(4):532-538",
                  "title": "Admission Chest CT Complements Fiberoptic Bronchoscopy in Prediction of Adverse Outcomes in Thermally Injured Patients"
                },
                "components": [
                  {
                    "factor": "q1",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  },
                  {
                    "factor": "q2",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  },
                  {
                    "factor": "q3",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  },
                  {
                    "factor": "q4",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "rads",
                "formula_expression": "RADS = q1 + q2 + q3 + q4; each quadrant worst finding on one 1-cm axial CT slice (Oh 2012 radiologist's score as reprinted in Dries/Walker 2015 Table 2): normal 0, interstitial (increased interstitial markings) 1, ground_glass 2, consolidation 3; four quadrants (not eight); range 0-12; high iff score > 8 per slice",
                "high": false,
                "max_score": 12,
                "q1": "normal",
                "q2": "normal",
                "q3": "normal",
                "q4": "normal",
                "score": 0
              },
              {
                "citation": {
                  "authors": "Oh JS, Chung KK, Allen A, Batchinsky AI, Huzar T, King BT, et al.",
                  "doi": "10.1097/BCR.0b013e318237455f",
                  "id": "oh-2012",
                  "pmid": "22210063",
                  "source": "J Burn Care Res. 2012;33(4):532-538",
                  "title": "Admission Chest CT Complements Fiberoptic Bronchoscopy in Prediction of Adverse Outcomes in Thermally Injured Patients"
                },
                "components": [
                  {
                    "factor": "q1",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  },
                  {
                    "factor": "q2",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  },
                  {
                    "factor": "q3",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  },
                  {
                    "factor": "q4",
                    "points": 0,
                    "present": false,
                    "value": "normal"
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "rads",
                "formula_expression": "RADS = q1 + q2 + q3 + q4; each quadrant worst finding on one 1-cm axial CT slice (Oh 2012 radiologist's score as reprinted in Dries/Walker 2015 Table 2): normal 0, interstitial (increased interstitial markings) 1, ground_glass 2, consolidation 3; four quadrants (not eight); range 0-12; high iff score > 8 per slice",
                "high": false,
                "max_score": 12,
                "q1": "normal",
                "q2": "normal",
                "q3": "normal",
                "q4": "normal",
                "score": 0
              }
            ],
            "path": "/api/calc/rads"
          },
          "type": "json"
        }
      },
      "schema": {
        "$schema": "https://json-schema.org/draft/2020-12/schema",
        "properties": {
          "input": {
            "additionalProperties": false,
            "properties": {
              "body": {
                "additionalProperties": false,
                "properties": {
                  "items": {
                    "items": {
                      "properties": {
                        "q1": {
                          "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                          "enum": [
                            "normal",
                            "interstitial",
                            "ground_glass",
                            "consolidation"
                          ],
                          "type": "string"
                        },
                        "q2": {
                          "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                          "enum": [
                            "normal",
                            "interstitial",
                            "ground_glass",
                            "consolidation"
                          ],
                          "type": "string"
                        },
                        "q3": {
                          "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                          "enum": [
                            "normal",
                            "interstitial",
                            "ground_glass",
                            "consolidation"
                          ],
                          "type": "string"
                        },
                        "q4": {
                          "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                          "enum": [
                            "normal",
                            "interstitial",
                            "ground_glass",
                            "consolidation"
                          ],
                          "type": "string"
                        }
                      },
                      "required": [
                        "q1",
                        "q2",
                        "q3",
                        "q4"
                      ],
                      "type": "object"
                    },
                    "maxItems": 25,
                    "minItems": 1,
                    "type": "array"
                  }
                },
                "required": [
                  "items"
                ],
                "type": "object"
              },
              "headers": {
                "additionalProperties": {
                  "type": "string"
                },
                "type": "object"
              },
              "method": {
                "const": "POST",
                "type": "string"
              },
              "type": {
                "const": "http",
                "type": "string"
              }
            },
            "required": [
              "type",
              "method"
            ],
            "type": "object"
          },
          "output": {
            "properties": {
              "example": {
                "type": "object"
              },
              "type": {
                "type": "string"
              }
            },
            "required": [
              "type"
            ],
            "type": "object"
          }
        },
        "required": [
          "input"
        ],
        "type": "object"
      }
    }
  },
  "tags": [
    "rads",
    "chest-ct",
    "inhalation",
    "burns",
    "calculator",
    "bazaar"
  ],
  "sourceHost": "api.magentlab.com",
  "lastUpdated": "2026-10-13T11:56:46.637Z",
  "quality": {
    "calls30d": 5,
    "uniquePayers30d": 2,
    "lastCalledAt": "2026-10-13T11:56:46.493Z"
  },
  "metadata": {
    "serviceName": "magent",
    "extensions": {
      "bazaar": {
        "info": {
          "iconUrl": "https://api.magentlab.com/favicon.ico",
          "input": {
            "body": {
              "items": [
                {
                  "q1": "normal",
                  "q2": "normal",
                  "q3": "normal",
                  "q4": "normal"
                },
                {
                  "q1": "normal",
                  "q2": "normal",
                  "q3": "normal",
                  "q4": "normal"
                }
              ]
            },
            "method": "POST",
            "type": "http"
          },
          "output": {
            "example": {
              "count": 2,
              "items": [
                {
                  "citation": {
                    "authors": "Oh JS, Chung KK, Allen A, Batchinsky AI, Huzar T, King BT, et al.",
                    "doi": "10.1097/BCR.0b013e318237455f",
                    "id": "oh-2012",
                    "pmid": "22210063",
                    "source": "J Burn Care Res. 2012;33(4):532-538",
                    "title": "Admission Chest CT Complements Fiberoptic Bronchoscopy in Prediction of Adverse Outcomes in Thermally Injured Patients"
                  },
                  "components": [
                    {
                      "factor": "q1",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    },
                    {
                      "factor": "q2",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    },
                    {
                      "factor": "q3",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    },
                    {
                      "factor": "q4",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "rads",
                  "formula_expression": "RADS = q1 + q2 + q3 + q4; each quadrant worst finding on one 1-cm axial CT slice (Oh 2012 radiologist's score as reprinted in Dries/Walker 2015 Table 2): normal 0, interstitial (increased interstitial markings) 1, ground_glass 2, consolidation 3; four quadrants (not eight); range 0-12; high iff score > 8 per slice",
                  "high": false,
                  "max_score": 12,
                  "q1": "normal",
                  "q2": "normal",
                  "q3": "normal",
                  "q4": "normal",
                  "score": 0
                },
                {
                  "citation": {
                    "authors": "Oh JS, Chung KK, Allen A, Batchinsky AI, Huzar T, King BT, et al.",
                    "doi": "10.1097/BCR.0b013e318237455f",
                    "id": "oh-2012",
                    "pmid": "22210063",
                    "source": "J Burn Care Res. 2012;33(4):532-538",
                    "title": "Admission Chest CT Complements Fiberoptic Bronchoscopy in Prediction of Adverse Outcomes in Thermally Injured Patients"
                  },
                  "components": [
                    {
                      "factor": "q1",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    },
                    {
                      "factor": "q2",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    },
                    {
                      "factor": "q3",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    },
                    {
                      "factor": "q4",
                      "points": 0,
                      "present": false,
                      "value": "normal"
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "rads",
                  "formula_expression": "RADS = q1 + q2 + q3 + q4; each quadrant worst finding on one 1-cm axial CT slice (Oh 2012 radiologist's score as reprinted in Dries/Walker 2015 Table 2): normal 0, interstitial (increased interstitial markings) 1, ground_glass 2, consolidation 3; four quadrants (not eight); range 0-12; high iff score > 8 per slice",
                  "high": false,
                  "max_score": 12,
                  "q1": "normal",
                  "q2": "normal",
                  "q3": "normal",
                  "q4": "normal",
                  "score": 0
                }
              ],
              "path": "/api/calc/rads"
            },
            "type": "json"
          }
        },
        "schema": {
          "$schema": "https://json-schema.org/draft/2020-12/schema",
          "properties": {
            "input": {
              "additionalProperties": false,
              "properties": {
                "body": {
                  "additionalProperties": false,
                  "properties": {
                    "items": {
                      "items": {
                        "properties": {
                          "q1": {
                            "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                            "enum": [
                              "normal",
                              "interstitial",
                              "ground_glass",
                              "consolidation"
                            ],
                            "type": "string"
                          },
                          "q2": {
                            "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                            "enum": [
                              "normal",
                              "interstitial",
                              "ground_glass",
                              "consolidation"
                            ],
                            "type": "string"
                          },
                          "q3": {
                            "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                            "enum": [
                              "normal",
                              "interstitial",
                              "ground_glass",
                              "consolidation"
                            ],
                            "type": "string"
                          },
                          "q4": {
                            "description": "Caller-assigned worst finding in that quadrant on one 1-cm axial chest CT slice (Oh 2012 radiologist's score; four quadrants, not eight): normal (0), interstitial / increased interstitial markings (1), ground_glass (2), or consolidation (3). magent does not interpret CT.",
                            "enum": [
                              "normal",
                              "interstitial",
                              "ground_glass",
                              "consolidation"
                            ],
                            "type": "string"
                          }
                        },
                        "required": [
                          "q1",
                          "q2",
                          "q3",
                          "q4"
                        ],
                        "type": "object"
                      },
                      "maxItems": 25,
                      "minItems": 1,
                      "type": "array"
                    }
                  },
                  "required": [
                    "items"
                  ],
                  "type": "object"
                },
                "headers": {
                  "additionalProperties": {
                    "type": "string"
                  },
                  "type": "object"
                },
                "method": {
                  "const": "POST",
                  "type": "string"
                },
                "type": {
                  "const": "http",
                  "type": "string"
                }
              },
              "required": [
                "type",
                "method"
              ],
              "type": "object"
            },
            "output": {
              "properties": {
                "example": {
                  "type": "object"
                },
                "type": {
                  "type": "string"
                }
              },
              "required": [
                "type"
              ],
              "type": "object"
            }
          },
          "required": [
            "input"
          ],
          "type": "object"
        }
      }
    }
  },
  "liveness": {
    "reliability": null
  },
  "verified": false,
  "featured": false,
  "provider": {
    "host": "api.magentlab.com",
    "manifest_name": "api.magentlab.com",
    "source": "cdp-mirror",
    "source_manifest_url": "https://api.cdp.coinbase.com/platform/v2/x402/discovery/resources",
    "submitted_at": "2026-10-14T01:15:01.050Z"
  },
  "exampleResponse": {
    "example": {},
    "type": "string"
  }
}