{
  "x402Version": 2,
  "id": 39268,
  "slug": "39268",
  "resource": "https://api.magentlab.com/api/calc/canadian_cspine",
  "description": "Canadian C-spine rule (Stiell 2001). Cervical radiography is indicated if any high-risk factor is present (age ≥65, dangerous mechanism, or paresthesias in the extremities). If none, radiography is indicated unless at least one low-risk factor allows safe range-of-motion assessment and the patient can rotate the neck 45° left and right. Not a diagnosis, not NEXUS, and not pediatric. For alert, stable blunt-trauma adults with GCS 15. magent does not examine the neck.",
  "type": "http",
  "serviceName": "magent",
  "resourceType": "Agent Service",
  "accepts": [
    {
      "scheme": "exact",
      "network": "eip155:8453",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "amount": "5000",
      "amountUsd": 0.005,
      "maxTimeoutSeconds": 600
    }
  ],
  "outputSchema": {
    "properties": {
      "example": {
        "type": "object"
      },
      "type": {
        "type": "string"
      }
    },
    "required": [
      "type"
    ],
    "type": "object"
  },
  "extensions": {
    "bazaar": {
      "info": {
        "iconUrl": "https://api.magentlab.com/favicon.ico",
        "input": {
          "body": {
            "items": [
              {
                "able_to_rotate_45": true,
                "age": 40,
                "ambulatory_since_injury": false,
                "dangerous_mechanism": false,
                "delayed_neck_pain": true,
                "midline_cspine_tenderness": true,
                "paresthesias_extremities": false,
                "simple_rear_end_mvc": false,
                "sitting_in_ed": false
              },
              {
                "able_to_rotate_45": true,
                "age": 40,
                "ambulatory_since_injury": false,
                "dangerous_mechanism": false,
                "delayed_neck_pain": true,
                "midline_cspine_tenderness": true,
                "paresthesias_extremities": false,
                "simple_rear_end_mvc": false,
                "sitting_in_ed": false
              }
            ]
          },
          "method": "POST",
          "type": "http"
        },
        "output": {
          "example": {
            "count": 2,
            "items": [
              {
                "able_to_rotate_45": true,
                "age_years": 40,
                "citation": {
                  "authors": "Stiell IG, Wells GA, Vandemheen KL, et al.",
                  "doi": "10.1001/jama.286.15.1841",
                  "id": "stiell-2001",
                  "source": "JAMA. 2001;286(15):1841-1848",
                  "title": "The Canadian C-spine rule for radiography in alert and stable trauma patients"
                },
                "criteria": [
                  {
                    "age_ge_65": false,
                    "dangerous_mechanism": false,
                    "factor": "high_risk",
                    "met": false,
                    "paresthesias_extremities": false,
                    "value": 40
                  },
                  {
                    "ambulatory_since_injury": false,
                    "delayed_neck_pain": true,
                    "factor": "low_risk_allows_rom",
                    "met": true,
                    "midline_cspine_tenderness": true,
                    "simple_rear_end_mvc": false,
                    "sitting_in_ed": false
                  },
                  {
                    "factor": "able_to_rotate_45",
                    "met": true
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "canadian_c_spine",
                "formula_expression": "xray indicated if any high-risk (age >= 65 or dangerous_mechanism or paresthesias_extremities); else if no low-risk allowing ROM (simple_rear_end_mvc or sitting_in_ed or ambulatory_since_injury or delayed_neck_pain or midline_cspine_tenderness false); else if not able_to_rotate_45",
                "high_risk": false,
                "low_risk_allows_rom": true,
                "xray_indicated": false
              },
              {
                "able_to_rotate_45": true,
                "age_years": 40,
                "citation": {
                  "authors": "Stiell IG, Wells GA, Vandemheen KL, et al.",
                  "doi": "10.1001/jama.286.15.1841",
                  "id": "stiell-2001",
                  "source": "JAMA. 2001;286(15):1841-1848",
                  "title": "The Canadian C-spine rule for radiography in alert and stable trauma patients"
                },
                "criteria": [
                  {
                    "age_ge_65": false,
                    "dangerous_mechanism": false,
                    "factor": "high_risk",
                    "met": false,
                    "paresthesias_extremities": false,
                    "value": 40
                  },
                  {
                    "ambulatory_since_injury": false,
                    "delayed_neck_pain": true,
                    "factor": "low_risk_allows_rom",
                    "met": true,
                    "midline_cspine_tenderness": true,
                    "simple_rear_end_mvc": false,
                    "sitting_in_ed": false
                  },
                  {
                    "factor": "able_to_rotate_45",
                    "met": true
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "canadian_c_spine",
                "formula_expression": "xray indicated if any high-risk (age >= 65 or dangerous_mechanism or paresthesias_extremities); else if no low-risk allowing ROM (simple_rear_end_mvc or sitting_in_ed or ambulatory_since_injury or delayed_neck_pain or midline_cspine_tenderness false); else if not able_to_rotate_45",
                "high_risk": false,
                "low_risk_allows_rom": true,
                "xray_indicated": false
              }
            ],
            "path": "/api/calc/canadian_cspine"
          },
          "type": "json"
        }
      },
      "schema": {
        "$schema": "https://json-schema.org/draft/2020-12/schema",
        "properties": {
          "input": {
            "additionalProperties": false,
            "properties": {
              "body": {
                "additionalProperties": false,
                "properties": {
                  "items": {
                    "items": {
                      "properties": {
                        "able_to_rotate_45": {
                          "description": "Able to actively rotate the neck 45 degrees left and right. true or false as assigned by the caller. Consulted only when there is no high-risk factor and at least one low-risk factor.",
                          "type": "boolean"
                        },
                        "age": {
                          "description": "Age in years (18-120). Age ≥65 is a high-risk factor that mandates radiography; 64 does not.",
                          "type": "integer"
                        },
                        "ambulatory_since_injury": {
                          "description": "Ambulatory at any time since injury. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment.",
                          "type": "boolean"
                        },
                        "dangerous_mechanism": {
                          "description": "Dangerous mechanism as assigned by the caller. true or false. High-risk; when true, radiography is indicated without range-of-motion assessment.",
                          "type": "boolean"
                        },
                        "delayed_neck_pain": {
                          "description": "Delayed onset of neck pain. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment.",
                          "type": "boolean"
                        },
                        "midline_cspine_tenderness": {
                          "description": "Midline cervical-spine tenderness. true or false as assigned by the caller. Absence of midline tenderness (false) is a low-risk factor that can allow safe range-of-motion assessment.",
                          "type": "boolean"
                        },
                        "paresthesias_extremities": {
                          "description": "Paresthesias in the extremities. true or false as assigned by the caller. High-risk; when true, radiography is indicated without range-of-motion assessment.",
                          "type": "boolean"
                        },
                        "simple_rear_end_mvc": {
                          "description": "Simple rear-end motor vehicle collision as assigned by the caller. true or false. A low-risk factor that can allow safe range-of-motion assessment.",
                          "type": "boolean"
                        },
                        "sitting_in_ed": {
                          "description": "Sitting position in the emergency department. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment.",
                          "type": "boolean"
                        }
                      },
                      "required": [
                        "age",
                        "dangerous_mechanism",
                        "paresthesias_extremities",
                        "simple_rear_end_mvc",
                        "sitting_in_ed",
                        "ambulatory_since_injury",
                        "delayed_neck_pain",
                        "midline_cspine_tenderness",
                        "able_to_rotate_45"
                      ],
                      "type": "object"
                    },
                    "maxItems": 25,
                    "minItems": 1,
                    "type": "array"
                  }
                },
                "required": [
                  "items"
                ],
                "type": "object"
              },
              "headers": {
                "additionalProperties": {
                  "type": "string"
                },
                "type": "object"
              },
              "method": {
                "const": "POST",
                "type": "string"
              },
              "type": {
                "const": "http",
                "type": "string"
              }
            },
            "required": [
              "type",
              "method"
            ],
            "type": "object"
          },
          "output": {
            "properties": {
              "example": {
                "type": "object"
              },
              "type": {
                "type": "string"
              }
            },
            "required": [
              "type"
            ],
            "type": "object"
          }
        },
        "required": [
          "input"
        ],
        "type": "object"
      }
    }
  },
  "tags": [
    "canadian-c-spine",
    "c-spine",
    "radiography",
    "emergency",
    "trauma",
    "bazaar"
  ],
  "sourceHost": "api.magentlab.com",
  "lastUpdated": "2026-10-13T00:56:42.743Z",
  "quality": {
    "calls30d": 5,
    "uniquePayers30d": 2,
    "lastCalledAt": "2026-10-13T00:56:42.606Z"
  },
  "metadata": {
    "serviceName": "magent",
    "extensions": {
      "bazaar": {
        "info": {
          "iconUrl": "https://api.magentlab.com/favicon.ico",
          "input": {
            "body": {
              "items": [
                {
                  "able_to_rotate_45": true,
                  "age": 40,
                  "ambulatory_since_injury": false,
                  "dangerous_mechanism": false,
                  "delayed_neck_pain": true,
                  "midline_cspine_tenderness": true,
                  "paresthesias_extremities": false,
                  "simple_rear_end_mvc": false,
                  "sitting_in_ed": false
                },
                {
                  "able_to_rotate_45": true,
                  "age": 40,
                  "ambulatory_since_injury": false,
                  "dangerous_mechanism": false,
                  "delayed_neck_pain": true,
                  "midline_cspine_tenderness": true,
                  "paresthesias_extremities": false,
                  "simple_rear_end_mvc": false,
                  "sitting_in_ed": false
                }
              ]
            },
            "method": "POST",
            "type": "http"
          },
          "output": {
            "example": {
              "count": 2,
              "items": [
                {
                  "able_to_rotate_45": true,
                  "age_years": 40,
                  "citation": {
                    "authors": "Stiell IG, Wells GA, Vandemheen KL, et al.",
                    "doi": "10.1001/jama.286.15.1841",
                    "id": "stiell-2001",
                    "source": "JAMA. 2001;286(15):1841-1848",
                    "title": "The Canadian C-spine rule for radiography in alert and stable trauma patients"
                  },
                  "criteria": [
                    {
                      "age_ge_65": false,
                      "dangerous_mechanism": false,
                      "factor": "high_risk",
                      "met": false,
                      "paresthesias_extremities": false,
                      "value": 40
                    },
                    {
                      "ambulatory_since_injury": false,
                      "delayed_neck_pain": true,
                      "factor": "low_risk_allows_rom",
                      "met": true,
                      "midline_cspine_tenderness": true,
                      "simple_rear_end_mvc": false,
                      "sitting_in_ed": false
                    },
                    {
                      "factor": "able_to_rotate_45",
                      "met": true
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "canadian_c_spine",
                  "formula_expression": "xray indicated if any high-risk (age >= 65 or dangerous_mechanism or paresthesias_extremities); else if no low-risk allowing ROM (simple_rear_end_mvc or sitting_in_ed or ambulatory_since_injury or delayed_neck_pain or midline_cspine_tenderness false); else if not able_to_rotate_45",
                  "high_risk": false,
                  "low_risk_allows_rom": true,
                  "xray_indicated": false
                },
                {
                  "able_to_rotate_45": true,
                  "age_years": 40,
                  "citation": {
                    "authors": "Stiell IG, Wells GA, Vandemheen KL, et al.",
                    "doi": "10.1001/jama.286.15.1841",
                    "id": "stiell-2001",
                    "source": "JAMA. 2001;286(15):1841-1848",
                    "title": "The Canadian C-spine rule for radiography in alert and stable trauma patients"
                  },
                  "criteria": [
                    {
                      "age_ge_65": false,
                      "dangerous_mechanism": false,
                      "factor": "high_risk",
                      "met": false,
                      "paresthesias_extremities": false,
                      "value": 40
                    },
                    {
                      "ambulatory_since_injury": false,
                      "delayed_neck_pain": true,
                      "factor": "low_risk_allows_rom",
                      "met": true,
                      "midline_cspine_tenderness": true,
                      "simple_rear_end_mvc": false,
                      "sitting_in_ed": false
                    },
                    {
                      "factor": "able_to_rotate_45",
                      "met": true
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "canadian_c_spine",
                  "formula_expression": "xray indicated if any high-risk (age >= 65 or dangerous_mechanism or paresthesias_extremities); else if no low-risk allowing ROM (simple_rear_end_mvc or sitting_in_ed or ambulatory_since_injury or delayed_neck_pain or midline_cspine_tenderness false); else if not able_to_rotate_45",
                  "high_risk": false,
                  "low_risk_allows_rom": true,
                  "xray_indicated": false
                }
              ],
              "path": "/api/calc/canadian_cspine"
            },
            "type": "json"
          }
        },
        "schema": {
          "$schema": "https://json-schema.org/draft/2020-12/schema",
          "properties": {
            "input": {
              "additionalProperties": false,
              "properties": {
                "body": {
                  "additionalProperties": false,
                  "properties": {
                    "items": {
                      "items": {
                        "properties": {
                          "able_to_rotate_45": {
                            "description": "Able to actively rotate the neck 45 degrees left and right. true or false as assigned by the caller. Consulted only when there is no high-risk factor and at least one low-risk factor.",
                            "type": "boolean"
                          },
                          "age": {
                            "description": "Age in years (18-120). Age ≥65 is a high-risk factor that mandates radiography; 64 does not.",
                            "type": "integer"
                          },
                          "ambulatory_since_injury": {
                            "description": "Ambulatory at any time since injury. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment.",
                            "type": "boolean"
                          },
                          "dangerous_mechanism": {
                            "description": "Dangerous mechanism as assigned by the caller. true or false. High-risk; when true, radiography is indicated without range-of-motion assessment.",
                            "type": "boolean"
                          },
                          "delayed_neck_pain": {
                            "description": "Delayed onset of neck pain. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment.",
                            "type": "boolean"
                          },
                          "midline_cspine_tenderness": {
                            "description": "Midline cervical-spine tenderness. true or false as assigned by the caller. Absence of midline tenderness (false) is a low-risk factor that can allow safe range-of-motion assessment.",
                            "type": "boolean"
                          },
                          "paresthesias_extremities": {
                            "description": "Paresthesias in the extremities. true or false as assigned by the caller. High-risk; when true, radiography is indicated without range-of-motion assessment.",
                            "type": "boolean"
                          },
                          "simple_rear_end_mvc": {
                            "description": "Simple rear-end motor vehicle collision as assigned by the caller. true or false. A low-risk factor that can allow safe range-of-motion assessment.",
                            "type": "boolean"
                          },
                          "sitting_in_ed": {
                            "description": "Sitting position in the emergency department. true or false as assigned by the caller. A low-risk factor that can allow safe range-of-motion assessment.",
                            "type": "boolean"
                          }
                        },
                        "required": [
                          "age",
                          "dangerous_mechanism",
                          "paresthesias_extremities",
                          "simple_rear_end_mvc",
                          "sitting_in_ed",
                          "ambulatory_since_injury",
                          "delayed_neck_pain",
                          "midline_cspine_tenderness",
                          "able_to_rotate_45"
                        ],
                        "type": "object"
                      },
                      "maxItems": 25,
                      "minItems": 1,
                      "type": "array"
                    }
                  },
                  "required": [
                    "items"
                  ],
                  "type": "object"
                },
                "headers": {
                  "additionalProperties": {
                    "type": "string"
                  },
                  "type": "object"
                },
                "method": {
                  "const": "POST",
                  "type": "string"
                },
                "type": {
                  "const": "http",
                  "type": "string"
                }
              },
              "required": [
                "type",
                "method"
              ],
              "type": "object"
            },
            "output": {
              "properties": {
                "example": {
                  "type": "object"
                },
                "type": {
                  "type": "string"
                }
              },
              "required": [
                "type"
              ],
              "type": "object"
            }
          },
          "required": [
            "input"
          ],
          "type": "object"
        }
      }
    }
  },
  "liveness": {
    "reliability": null
  },
  "verified": false,
  "featured": false,
  "provider": {
    "host": "api.magentlab.com",
    "manifest_name": "api.magentlab.com",
    "source": "cdp-mirror",
    "source_manifest_url": "https://api.cdp.coinbase.com/platform/v2/x402/discovery/resources",
    "submitted_at": "2026-10-14T01:15:01.050Z"
  },
  "exampleResponse": {
    "example": {},
    "type": "string"
  }
}