{
  "x402Version": 2,
  "id": 39315,
  "slug": "39315",
  "resource": "https://api.magentlab.com/api/calc/aldrete",
  "description": "Aldrete 1970 postanesthetic recovery score from five caller-assigned 0-2 signs (activity, respiration, circulation, consciousness, color), summed to 0-10. Returns 0_to_7 (close observation), 8_to_9 (acceptable for recovery-room discharge to the ward), or 10 (ideal). Deterministic published score with citation; not the 1995 SpO2 revision; not PADSS; not a discharge order.",
  "type": "http",
  "serviceName": "magent",
  "resourceType": "Agent Service",
  "accepts": [
    {
      "scheme": "exact",
      "network": "eip155:8453",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "amount": "5000",
      "amountUsd": 0.005,
      "maxTimeoutSeconds": 600
    }
  ],
  "outputSchema": {
    "properties": {
      "example": {
        "type": "object"
      },
      "type": {
        "type": "string"
      }
    },
    "required": [
      "type"
    ],
    "type": "object"
  },
  "extensions": {
    "bazaar": {
      "info": {
        "iconUrl": "https://api.magentlab.com/favicon.ico",
        "input": {
          "body": {
            "items": [
              {
                "activity": 2,
                "circulation": 2,
                "color": 2,
                "consciousness": 2,
                "respiration": 2
              },
              {
                "activity": 2,
                "circulation": 2,
                "color": 2,
                "consciousness": 2,
                "respiration": 2
              }
            ]
          },
          "method": "POST",
          "type": "http"
        },
        "output": {
          "example": {
            "count": 2,
            "items": [
              {
                "category": "10",
                "citation": {
                  "authors": "Aldrete JA, Kroulik D",
                  "doi": "10.1213/00000539-197011000-00020",
                  "id": "aldrete-1970",
                  "pmid": "5534693",
                  "source": "Anesth Analg. 1970;49(6):924-934",
                  "title": "A postanesthetic recovery score"
                },
                "components": [
                  {
                    "factor": "activity",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "respiration",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "circulation",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "consciousness",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "color",
                    "points": 2,
                    "present": true,
                    "value": 2
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "aldrete",
                "formula_expression": "Aldrete = activity + respiration + circulation + consciousness + color; each 0-2; max 10; 8-9 acceptable for recovery-room discharge to ward; 10 ideal; 0-7 close observation (Aldrete 1970)",
                "max_score": 10,
                "score": 10
              },
              {
                "category": "10",
                "citation": {
                  "authors": "Aldrete JA, Kroulik D",
                  "doi": "10.1213/00000539-197011000-00020",
                  "id": "aldrete-1970",
                  "pmid": "5534693",
                  "source": "Anesth Analg. 1970;49(6):924-934",
                  "title": "A postanesthetic recovery score"
                },
                "components": [
                  {
                    "factor": "activity",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "respiration",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "circulation",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "consciousness",
                    "points": 2,
                    "present": true,
                    "value": 2
                  },
                  {
                    "factor": "color",
                    "points": 2,
                    "present": true,
                    "value": 2
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "aldrete",
                "formula_expression": "Aldrete = activity + respiration + circulation + consciousness + color; each 0-2; max 10; 8-9 acceptable for recovery-room discharge to ward; 10 ideal; 0-7 close observation (Aldrete 1970)",
                "max_score": 10,
                "score": 10
              }
            ],
            "path": "/api/calc/aldrete"
          },
          "type": "json"
        }
      },
      "schema": {
        "$schema": "https://json-schema.org/draft/2020-12/schema",
        "properties": {
          "input": {
            "additionalProperties": false,
            "properties": {
              "body": {
                "additionalProperties": false,
                "properties": {
                  "items": {
                    "items": {
                      "properties": {
                        "activity": {
                          "description": "Muscle activity (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = moves 4 extremities voluntarily or on command; 1 = 2 extremities; 0 = none. magent does not examine the patient.",
                          "type": "integer"
                        },
                        "circulation": {
                          "description": "Circulation (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = BP within 20% of preanesthetic level; 1 = BP 20-50% of preanesthetic; 0 = BP 50% or more from preanesthetic. magent does not measure blood pressure.",
                          "type": "integer"
                        },
                        "color": {
                          "description": "Color (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = pink; 1 = pale, dusky, blotchy, jaundiced, or other; 0 = cyanotic. Not the 1995 SpO2 revision. magent does not observe skin color.",
                          "type": "integer"
                        },
                        "consciousness": {
                          "description": "Consciousness (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = fully awake; 1 = arousable on calling; 0 = not responding. magent does not examine the patient.",
                          "type": "integer"
                        },
                        "respiration": {
                          "description": "Respiration (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = able to deep breathe and cough freely; 1 = dyspnea or limited breathing; 0 = apneic. magent does not auscultate.",
                          "type": "integer"
                        }
                      },
                      "required": [
                        "activity",
                        "respiration",
                        "circulation",
                        "consciousness",
                        "color"
                      ],
                      "type": "object"
                    },
                    "maxItems": 25,
                    "minItems": 1,
                    "type": "array"
                  }
                },
                "required": [
                  "items"
                ],
                "type": "object"
              },
              "headers": {
                "additionalProperties": {
                  "type": "string"
                },
                "type": "object"
              },
              "method": {
                "const": "POST",
                "type": "string"
              },
              "type": {
                "const": "http",
                "type": "string"
              }
            },
            "required": [
              "type",
              "method"
            ],
            "type": "object"
          },
          "output": {
            "properties": {
              "example": {
                "type": "object"
              },
              "type": {
                "type": "string"
              }
            },
            "required": [
              "type"
            ],
            "type": "object"
          }
        },
        "required": [
          "input"
        ],
        "type": "object"
      }
    }
  },
  "tags": [
    "aldrete",
    "pacu",
    "anesthesia",
    "recovery",
    "calculator",
    "bazaar"
  ],
  "sourceHost": "api.magentlab.com",
  "lastUpdated": "2026-10-12T23:30:52.03Z",
  "quality": {
    "calls30d": 5,
    "uniquePayers30d": 2,
    "lastCalledAt": "2026-10-12T23:30:51.873Z"
  },
  "metadata": {
    "serviceName": "magent",
    "extensions": {
      "bazaar": {
        "info": {
          "iconUrl": "https://api.magentlab.com/favicon.ico",
          "input": {
            "body": {
              "items": [
                {
                  "activity": 2,
                  "circulation": 2,
                  "color": 2,
                  "consciousness": 2,
                  "respiration": 2
                },
                {
                  "activity": 2,
                  "circulation": 2,
                  "color": 2,
                  "consciousness": 2,
                  "respiration": 2
                }
              ]
            },
            "method": "POST",
            "type": "http"
          },
          "output": {
            "example": {
              "count": 2,
              "items": [
                {
                  "category": "10",
                  "citation": {
                    "authors": "Aldrete JA, Kroulik D",
                    "doi": "10.1213/00000539-197011000-00020",
                    "id": "aldrete-1970",
                    "pmid": "5534693",
                    "source": "Anesth Analg. 1970;49(6):924-934",
                    "title": "A postanesthetic recovery score"
                  },
                  "components": [
                    {
                      "factor": "activity",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "respiration",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "circulation",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "consciousness",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "color",
                      "points": 2,
                      "present": true,
                      "value": 2
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "aldrete",
                  "formula_expression": "Aldrete = activity + respiration + circulation + consciousness + color; each 0-2; max 10; 8-9 acceptable for recovery-room discharge to ward; 10 ideal; 0-7 close observation (Aldrete 1970)",
                  "max_score": 10,
                  "score": 10
                },
                {
                  "category": "10",
                  "citation": {
                    "authors": "Aldrete JA, Kroulik D",
                    "doi": "10.1213/00000539-197011000-00020",
                    "id": "aldrete-1970",
                    "pmid": "5534693",
                    "source": "Anesth Analg. 1970;49(6):924-934",
                    "title": "A postanesthetic recovery score"
                  },
                  "components": [
                    {
                      "factor": "activity",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "respiration",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "circulation",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "consciousness",
                      "points": 2,
                      "present": true,
                      "value": 2
                    },
                    {
                      "factor": "color",
                      "points": 2,
                      "present": true,
                      "value": 2
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "aldrete",
                  "formula_expression": "Aldrete = activity + respiration + circulation + consciousness + color; each 0-2; max 10; 8-9 acceptable for recovery-room discharge to ward; 10 ideal; 0-7 close observation (Aldrete 1970)",
                  "max_score": 10,
                  "score": 10
                }
              ],
              "path": "/api/calc/aldrete"
            },
            "type": "json"
          }
        },
        "schema": {
          "$schema": "https://json-schema.org/draft/2020-12/schema",
          "properties": {
            "input": {
              "additionalProperties": false,
              "properties": {
                "body": {
                  "additionalProperties": false,
                  "properties": {
                    "items": {
                      "items": {
                        "properties": {
                          "activity": {
                            "description": "Muscle activity (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = moves 4 extremities voluntarily or on command; 1 = 2 extremities; 0 = none. magent does not examine the patient.",
                            "type": "integer"
                          },
                          "circulation": {
                            "description": "Circulation (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = BP within 20% of preanesthetic level; 1 = BP 20-50% of preanesthetic; 0 = BP 50% or more from preanesthetic. magent does not measure blood pressure.",
                            "type": "integer"
                          },
                          "color": {
                            "description": "Color (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = pink; 1 = pale, dusky, blotchy, jaundiced, or other; 0 = cyanotic. Not the 1995 SpO2 revision. magent does not observe skin color.",
                            "type": "integer"
                          },
                          "consciousness": {
                            "description": "Consciousness (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = fully awake; 1 = arousable on calling; 0 = not responding. magent does not examine the patient.",
                            "type": "integer"
                          },
                          "respiration": {
                            "description": "Respiration (Aldrete 1970). Integer 0, 1, or 2 as assigned by the caller. 2 = able to deep breathe and cough freely; 1 = dyspnea or limited breathing; 0 = apneic. magent does not auscultate.",
                            "type": "integer"
                          }
                        },
                        "required": [
                          "activity",
                          "respiration",
                          "circulation",
                          "consciousness",
                          "color"
                        ],
                        "type": "object"
                      },
                      "maxItems": 25,
                      "minItems": 1,
                      "type": "array"
                    }
                  },
                  "required": [
                    "items"
                  ],
                  "type": "object"
                },
                "headers": {
                  "additionalProperties": {
                    "type": "string"
                  },
                  "type": "object"
                },
                "method": {
                  "const": "POST",
                  "type": "string"
                },
                "type": {
                  "const": "http",
                  "type": "string"
                }
              },
              "required": [
                "type",
                "method"
              ],
              "type": "object"
            },
            "output": {
              "properties": {
                "example": {
                  "type": "object"
                },
                "type": {
                  "type": "string"
                }
              },
              "required": [
                "type"
              ],
              "type": "object"
            }
          },
          "required": [
            "input"
          ],
          "type": "object"
        }
      }
    }
  },
  "liveness": {
    "reliability": null
  },
  "verified": false,
  "featured": false,
  "provider": {
    "host": "api.magentlab.com",
    "manifest_name": "api.magentlab.com",
    "source": "cdp-mirror",
    "source_manifest_url": "https://api.cdp.coinbase.com/platform/v2/x402/discovery/resources",
    "submitted_at": "2026-10-14T01:15:01.050Z"
  },
  "exampleResponse": {
    "example": {},
    "type": "string"
  }
}