{
  "x402Version": 2,
  "id": 39320,
  "slug": "39320",
  "resource": "https://api.magentlab.com/api/calc/add_rs",
  "description": "Rogers 2011 aortic dissection detection risk score (ADD-RS). One point per high-risk category with any marker (conditions, pain features, exam features); two markers in the same category still add only 1; max 3. Bands 0 / 1 / 2-3. Deterministic published score with citation. Not an imaging order, not ADvISED D-dimer rule-out; score 0 does not exclude dissection.",
  "type": "http",
  "serviceName": "magent",
  "resourceType": "Agent Service",
  "accepts": [
    {
      "scheme": "exact",
      "network": "eip155:8453",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "amount": "5000",
      "amountUsd": 0.005,
      "maxTimeoutSeconds": 600
    }
  ],
  "outputSchema": {
    "properties": {
      "example": {
        "type": "object"
      },
      "type": {
        "type": "string"
      }
    },
    "required": [
      "type"
    ],
    "type": "object"
  },
  "extensions": {
    "bazaar": {
      "info": {
        "iconUrl": "https://api.magentlab.com/favicon.ico",
        "input": {
          "body": {
            "items": [
              {
                "family_aortic_disease": false,
                "focal_neuro_deficit_with_pain": false,
                "hypotension_or_shock": false,
                "known_aortic_valve_disease": false,
                "known_thoracic_aneurysm": false,
                "marfan_or_connective_tissue": false,
                "new_ai_murmur_with_pain": false,
                "pain_ripping_or_tearing": false,
                "pain_severe": false,
                "pain_sudden": false,
                "pulse_deficit_or_sbp_differential": false,
                "recent_aortic_manipulation": false
              },
              {
                "family_aortic_disease": false,
                "focal_neuro_deficit_with_pain": false,
                "hypotension_or_shock": false,
                "known_aortic_valve_disease": false,
                "known_thoracic_aneurysm": false,
                "marfan_or_connective_tissue": false,
                "new_ai_murmur_with_pain": false,
                "pain_ripping_or_tearing": false,
                "pain_severe": false,
                "pain_sudden": false,
                "pulse_deficit_or_sbp_differential": false,
                "recent_aortic_manipulation": false
              }
            ]
          },
          "method": "POST",
          "type": "http"
        },
        "output": {
          "example": {
            "count": 2,
            "items": [
              {
                "add_rs_band": "0",
                "citation": {
                  "authors": "Rogers AM, Hermann LK, Booher AM, et al.",
                  "doi": "10.1161/CIRCULATIONAHA.110.988568",
                  "id": "rogers-2011",
                  "pmid": "21555704",
                  "source": "Circulation. 2011;123(20):2213-2218",
                  "title": "Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the international registry of acute aortic dissection"
                },
                "components": [
                  {
                    "factor": "high_risk_conditions",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "high_risk_pain",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "high_risk_exam",
                    "points": 0,
                    "present": false
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "add_rs",
                "formula_expression": "ADD-RS = 1 if any high-risk condition (Marfan/connective tissue, family aortic disease, known aortic valve disease, recent aortic manipulation, known thoracic aneurysm) + 1 if any high-risk pain feature of chest/back/abdominal pain (sudden, severe, ripping/tearing) + 1 if any high-risk exam feature (pulse deficit or SBP differential, focal neurologic deficit with pain, new AI murmur with pain, hypotension or shock); two markers in the same category still add only 1; max 3; Rogers 2011 bands 0 / 1 / 2-3 (2010 ACCF/AHA high-risk markers)",
                "max_score": 3,
                "score": 0
              },
              {
                "add_rs_band": "0",
                "citation": {
                  "authors": "Rogers AM, Hermann LK, Booher AM, et al.",
                  "doi": "10.1161/CIRCULATIONAHA.110.988568",
                  "id": "rogers-2011",
                  "pmid": "21555704",
                  "source": "Circulation. 2011;123(20):2213-2218",
                  "title": "Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the international registry of acute aortic dissection"
                },
                "components": [
                  {
                    "factor": "high_risk_conditions",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "high_risk_pain",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "high_risk_exam",
                    "points": 0,
                    "present": false
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "add_rs",
                "formula_expression": "ADD-RS = 1 if any high-risk condition (Marfan/connective tissue, family aortic disease, known aortic valve disease, recent aortic manipulation, known thoracic aneurysm) + 1 if any high-risk pain feature of chest/back/abdominal pain (sudden, severe, ripping/tearing) + 1 if any high-risk exam feature (pulse deficit or SBP differential, focal neurologic deficit with pain, new AI murmur with pain, hypotension or shock); two markers in the same category still add only 1; max 3; Rogers 2011 bands 0 / 1 / 2-3 (2010 ACCF/AHA high-risk markers)",
                "max_score": 3,
                "score": 0
              }
            ],
            "path": "/api/calc/add_rs"
          },
          "type": "json"
        }
      },
      "schema": {
        "$schema": "https://json-schema.org/draft/2020-12/schema",
        "properties": {
          "input": {
            "additionalProperties": false,
            "properties": {
              "body": {
                "additionalProperties": false,
                "properties": {
                  "items": {
                    "items": {
                      "properties": {
                        "family_aortic_disease": {
                          "description": "Family history of aortic disease (Rogers 2011 high-risk condition). true or false.",
                          "type": "boolean"
                        },
                        "focal_neuro_deficit_with_pain": {
                          "description": "Focal neurologic deficit in conjunction with pain (Rogers 2011 high-risk exam feature). true or false.",
                          "type": "boolean"
                        },
                        "hypotension_or_shock": {
                          "description": "Hypotension or shock state (Rogers 2011 high-risk exam feature). true or false.",
                          "type": "boolean"
                        },
                        "known_aortic_valve_disease": {
                          "description": "Known aortic valve disease (Rogers 2011 high-risk condition). true or false.",
                          "type": "boolean"
                        },
                        "known_thoracic_aneurysm": {
                          "description": "Known thoracic aortic aneurysm (Rogers 2011 high-risk condition). true or false.",
                          "type": "boolean"
                        },
                        "marfan_or_connective_tissue": {
                          "description": "Marfan syndrome or other connective-tissue disease (Rogers 2011 high-risk condition). true or false. Caller-assigned; magent does not diagnose a syndrome.",
                          "type": "boolean"
                        },
                        "new_ai_murmur_with_pain": {
                          "description": "New murmur of aortic insufficiency in conjunction with pain (Rogers 2011 high-risk exam feature). true or false. Caller-assigned; magent does not auscultate.",
                          "type": "boolean"
                        },
                        "pain_ripping_or_tearing": {
                          "description": "Chest, back, or abdominal pain described as ripping or tearing (Rogers 2011 high-risk pain feature). true or false.",
                          "type": "boolean"
                        },
                        "pain_severe": {
                          "description": "Chest, back, or abdominal pain of severe intensity (Rogers 2011 high-risk pain feature). true or false.",
                          "type": "boolean"
                        },
                        "pain_sudden": {
                          "description": "Chest, back, or abdominal pain of abrupt onset (Rogers 2011 high-risk pain feature). true or false.",
                          "type": "boolean"
                        },
                        "pulse_deficit_or_sbp_differential": {
                          "description": "Pulse deficit or systolic blood-pressure differential (Rogers 2011 high-risk exam feature). true or false. Caller-assigned; magent does not measure pulses.",
                          "type": "boolean"
                        },
                        "recent_aortic_manipulation": {
                          "description": "Recent aortic manipulation such as catheterization or cardiac surgery (Rogers 2011 high-risk condition). true or false.",
                          "type": "boolean"
                        }
                      },
                      "required": [
                        "marfan_or_connective_tissue",
                        "family_aortic_disease",
                        "known_aortic_valve_disease",
                        "recent_aortic_manipulation",
                        "known_thoracic_aneurysm",
                        "pain_sudden",
                        "pain_severe",
                        "pain_ripping_or_tearing",
                        "pulse_deficit_or_sbp_differential",
                        "focal_neuro_deficit_with_pain",
                        "new_ai_murmur_with_pain",
                        "hypotension_or_shock"
                      ],
                      "type": "object"
                    },
                    "maxItems": 25,
                    "minItems": 1,
                    "type": "array"
                  }
                },
                "required": [
                  "items"
                ],
                "type": "object"
              },
              "headers": {
                "additionalProperties": {
                  "type": "string"
                },
                "type": "object"
              },
              "method": {
                "const": "POST",
                "type": "string"
              },
              "type": {
                "const": "http",
                "type": "string"
              }
            },
            "required": [
              "type",
              "method"
            ],
            "type": "object"
          },
          "output": {
            "properties": {
              "example": {
                "type": "object"
              },
              "type": {
                "type": "string"
              }
            },
            "required": [
              "type"
            ],
            "type": "object"
          }
        },
        "required": [
          "input"
        ],
        "type": "object"
      }
    }
  },
  "tags": [
    "add-rs",
    "aortic-dissection",
    "acs",
    "calculator",
    "bazaar"
  ],
  "sourceHost": "api.magentlab.com",
  "lastUpdated": "2026-10-12T23:25:48.052Z",
  "quality": {
    "calls30d": 5,
    "uniquePayers30d": 2,
    "lastCalledAt": "2026-10-12T23:25:47.721Z"
  },
  "metadata": {
    "serviceName": "magent",
    "extensions": {
      "bazaar": {
        "info": {
          "iconUrl": "https://api.magentlab.com/favicon.ico",
          "input": {
            "body": {
              "items": [
                {
                  "family_aortic_disease": false,
                  "focal_neuro_deficit_with_pain": false,
                  "hypotension_or_shock": false,
                  "known_aortic_valve_disease": false,
                  "known_thoracic_aneurysm": false,
                  "marfan_or_connective_tissue": false,
                  "new_ai_murmur_with_pain": false,
                  "pain_ripping_or_tearing": false,
                  "pain_severe": false,
                  "pain_sudden": false,
                  "pulse_deficit_or_sbp_differential": false,
                  "recent_aortic_manipulation": false
                },
                {
                  "family_aortic_disease": false,
                  "focal_neuro_deficit_with_pain": false,
                  "hypotension_or_shock": false,
                  "known_aortic_valve_disease": false,
                  "known_thoracic_aneurysm": false,
                  "marfan_or_connective_tissue": false,
                  "new_ai_murmur_with_pain": false,
                  "pain_ripping_or_tearing": false,
                  "pain_severe": false,
                  "pain_sudden": false,
                  "pulse_deficit_or_sbp_differential": false,
                  "recent_aortic_manipulation": false
                }
              ]
            },
            "method": "POST",
            "type": "http"
          },
          "output": {
            "example": {
              "count": 2,
              "items": [
                {
                  "add_rs_band": "0",
                  "citation": {
                    "authors": "Rogers AM, Hermann LK, Booher AM, et al.",
                    "doi": "10.1161/CIRCULATIONAHA.110.988568",
                    "id": "rogers-2011",
                    "pmid": "21555704",
                    "source": "Circulation. 2011;123(20):2213-2218",
                    "title": "Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the international registry of acute aortic dissection"
                  },
                  "components": [
                    {
                      "factor": "high_risk_conditions",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "high_risk_pain",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "high_risk_exam",
                      "points": 0,
                      "present": false
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "add_rs",
                  "formula_expression": "ADD-RS = 1 if any high-risk condition (Marfan/connective tissue, family aortic disease, known aortic valve disease, recent aortic manipulation, known thoracic aneurysm) + 1 if any high-risk pain feature of chest/back/abdominal pain (sudden, severe, ripping/tearing) + 1 if any high-risk exam feature (pulse deficit or SBP differential, focal neurologic deficit with pain, new AI murmur with pain, hypotension or shock); two markers in the same category still add only 1; max 3; Rogers 2011 bands 0 / 1 / 2-3 (2010 ACCF/AHA high-risk markers)",
                  "max_score": 3,
                  "score": 0
                },
                {
                  "add_rs_band": "0",
                  "citation": {
                    "authors": "Rogers AM, Hermann LK, Booher AM, et al.",
                    "doi": "10.1161/CIRCULATIONAHA.110.988568",
                    "id": "rogers-2011",
                    "pmid": "21555704",
                    "source": "Circulation. 2011;123(20):2213-2218",
                    "title": "Sensitivity of the aortic dissection detection risk score, a novel guideline-based tool for identification of acute aortic dissection at initial presentation: results from the international registry of acute aortic dissection"
                  },
                  "components": [
                    {
                      "factor": "high_risk_conditions",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "high_risk_pain",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "high_risk_exam",
                      "points": 0,
                      "present": false
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "add_rs",
                  "formula_expression": "ADD-RS = 1 if any high-risk condition (Marfan/connective tissue, family aortic disease, known aortic valve disease, recent aortic manipulation, known thoracic aneurysm) + 1 if any high-risk pain feature of chest/back/abdominal pain (sudden, severe, ripping/tearing) + 1 if any high-risk exam feature (pulse deficit or SBP differential, focal neurologic deficit with pain, new AI murmur with pain, hypotension or shock); two markers in the same category still add only 1; max 3; Rogers 2011 bands 0 / 1 / 2-3 (2010 ACCF/AHA high-risk markers)",
                  "max_score": 3,
                  "score": 0
                }
              ],
              "path": "/api/calc/add_rs"
            },
            "type": "json"
          }
        },
        "schema": {
          "$schema": "https://json-schema.org/draft/2020-12/schema",
          "properties": {
            "input": {
              "additionalProperties": false,
              "properties": {
                "body": {
                  "additionalProperties": false,
                  "properties": {
                    "items": {
                      "items": {
                        "properties": {
                          "family_aortic_disease": {
                            "description": "Family history of aortic disease (Rogers 2011 high-risk condition). true or false.",
                            "type": "boolean"
                          },
                          "focal_neuro_deficit_with_pain": {
                            "description": "Focal neurologic deficit in conjunction with pain (Rogers 2011 high-risk exam feature). true or false.",
                            "type": "boolean"
                          },
                          "hypotension_or_shock": {
                            "description": "Hypotension or shock state (Rogers 2011 high-risk exam feature). true or false.",
                            "type": "boolean"
                          },
                          "known_aortic_valve_disease": {
                            "description": "Known aortic valve disease (Rogers 2011 high-risk condition). true or false.",
                            "type": "boolean"
                          },
                          "known_thoracic_aneurysm": {
                            "description": "Known thoracic aortic aneurysm (Rogers 2011 high-risk condition). true or false.",
                            "type": "boolean"
                          },
                          "marfan_or_connective_tissue": {
                            "description": "Marfan syndrome or other connective-tissue disease (Rogers 2011 high-risk condition). true or false. Caller-assigned; magent does not diagnose a syndrome.",
                            "type": "boolean"
                          },
                          "new_ai_murmur_with_pain": {
                            "description": "New murmur of aortic insufficiency in conjunction with pain (Rogers 2011 high-risk exam feature). true or false. Caller-assigned; magent does not auscultate.",
                            "type": "boolean"
                          },
                          "pain_ripping_or_tearing": {
                            "description": "Chest, back, or abdominal pain described as ripping or tearing (Rogers 2011 high-risk pain feature). true or false.",
                            "type": "boolean"
                          },
                          "pain_severe": {
                            "description": "Chest, back, or abdominal pain of severe intensity (Rogers 2011 high-risk pain feature). true or false.",
                            "type": "boolean"
                          },
                          "pain_sudden": {
                            "description": "Chest, back, or abdominal pain of abrupt onset (Rogers 2011 high-risk pain feature). true or false.",
                            "type": "boolean"
                          },
                          "pulse_deficit_or_sbp_differential": {
                            "description": "Pulse deficit or systolic blood-pressure differential (Rogers 2011 high-risk exam feature). true or false. Caller-assigned; magent does not measure pulses.",
                            "type": "boolean"
                          },
                          "recent_aortic_manipulation": {
                            "description": "Recent aortic manipulation such as catheterization or cardiac surgery (Rogers 2011 high-risk condition). true or false.",
                            "type": "boolean"
                          }
                        },
                        "required": [
                          "marfan_or_connective_tissue",
                          "family_aortic_disease",
                          "known_aortic_valve_disease",
                          "recent_aortic_manipulation",
                          "known_thoracic_aneurysm",
                          "pain_sudden",
                          "pain_severe",
                          "pain_ripping_or_tearing",
                          "pulse_deficit_or_sbp_differential",
                          "focal_neuro_deficit_with_pain",
                          "new_ai_murmur_with_pain",
                          "hypotension_or_shock"
                        ],
                        "type": "object"
                      },
                      "maxItems": 25,
                      "minItems": 1,
                      "type": "array"
                    }
                  },
                  "required": [
                    "items"
                  ],
                  "type": "object"
                },
                "headers": {
                  "additionalProperties": {
                    "type": "string"
                  },
                  "type": "object"
                },
                "method": {
                  "const": "POST",
                  "type": "string"
                },
                "type": {
                  "const": "http",
                  "type": "string"
                }
              },
              "required": [
                "type",
                "method"
              ],
              "type": "object"
            },
            "output": {
              "properties": {
                "example": {
                  "type": "object"
                },
                "type": {
                  "type": "string"
                }
              },
              "required": [
                "type"
              ],
              "type": "object"
            }
          },
          "required": [
            "input"
          ],
          "type": "object"
        }
      }
    }
  },
  "liveness": {
    "reliability": null
  },
  "verified": false,
  "featured": false,
  "provider": {
    "host": "api.magentlab.com",
    "manifest_name": "api.magentlab.com",
    "source": "cdp-mirror",
    "source_manifest_url": "https://api.cdp.coinbase.com/platform/v2/x402/discovery/resources",
    "submitted_at": "2026-10-14T01:15:01.050Z"
  },
  "exampleResponse": {
    "example": {},
    "type": "string"
  }
}