{
  "x402Version": 2,
  "id": 39397,
  "slug": "39397",
  "resource": "https://api.magentlab.com/api/calc/hep",
  "description": "Cuker 2010 HEP score: eight features with signed weights (range -16 to 19). Magnitude of platelet fall, typical- or rapid-onset timing, nadir, thrombosis (at most one), SQ heparin skin necrosis, IV-bolus systemic reaction, bleeding, and other causes (select all; no other cause +3). Cutoff 2 was 100% sensitive / 60% specific vs the expert panel. Not a HIT diagnosis or 4Ts score. magent does not assay SRA or ELISA.",
  "type": "http",
  "serviceName": "magent",
  "resourceType": "Agent Service",
  "accepts": [
    {
      "scheme": "exact",
      "network": "eip155:8453",
      "payTo": "0x836Be278f1739fB4308091cD1852F7971Bc19Ee2",
      "asset": "0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913",
      "amount": "5000",
      "amountUsd": 0.005,
      "maxTimeoutSeconds": 600
    }
  ],
  "outputSchema": {
    "properties": {
      "example": {
        "type": "object"
      },
      "type": {
        "type": "string"
      }
    },
    "required": [
      "type"
    ],
    "type": "object"
  },
  "extensions": {
    "bazaar": {
      "info": {
        "iconUrl": "https://api.magentlab.com/favicon.ico",
        "input": {
          "body": {
            "items": [
              {
                "bleeding": false,
                "chronic_thrombocytopenia": false,
                "cpb_96h": false,
                "intra_arterial_device": false,
                "magnitude": "gt_50",
                "nadir": "gt_20",
                "new_drug_thrombocytopenia": false,
                "no_other_cause": true,
                "overt_dic": false,
                "severe_infection": false,
                "skin_necrosis": false,
                "systemic_reaction": false,
                "thrombosis": "typical_new_ge_4d",
                "timing": "typical_5_10"
              },
              {
                "bleeding": false,
                "chronic_thrombocytopenia": false,
                "cpb_96h": false,
                "intra_arterial_device": false,
                "magnitude": "gt_50",
                "nadir": "gt_20",
                "new_drug_thrombocytopenia": false,
                "no_other_cause": true,
                "overt_dic": false,
                "severe_infection": false,
                "skin_necrosis": false,
                "systemic_reaction": false,
                "thrombosis": "typical_new_ge_4d",
                "timing": "typical_5_10"
              }
            ]
          },
          "method": "POST",
          "type": "http"
        },
        "output": {
          "example": {
            "count": 2,
            "items": [
              {
                "citation": {
                  "authors": "Cuker A, Arepally G, Crowther MA, Rice L, Datko F, Hook K, Propert KJ, Kuter DJ, Ortel TL, Konkle BA, Cines DB",
                  "doi": "10.1111/j.1538-7836.2010.04059.x",
                  "id": "cuker-2010",
                  "pmid": "20854372",
                  "source": "J Thromb Haemost. 2010;8(12):2642-2650",
                  "title": "The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion"
                },
                "components": [
                  {
                    "factor": "magnitude",
                    "points": 3,
                    "present": true,
                    "value": "gt_50"
                  },
                  {
                    "factor": "timing",
                    "points": 3,
                    "present": true,
                    "value": "typical_5_10"
                  },
                  {
                    "factor": "nadir",
                    "points": 2,
                    "present": true,
                    "value": "gt_20"
                  },
                  {
                    "factor": "thrombosis",
                    "points": 3,
                    "present": true,
                    "value": "typical_new_ge_4d"
                  },
                  {
                    "factor": "skin_necrosis",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "systemic_reaction",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "bleeding",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "chronic_thrombocytopenia",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "new_drug_thrombocytopenia",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "severe_infection",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "overt_dic",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "intra_arterial_device",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "cpb_96h",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "no_other_cause",
                    "points": 3,
                    "present": true
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "hep",
                "formula_expression": "HEP = magnitude (lt_30 -1, 30_to_50 1, gt_50 3) + timing (typical_lt_4 -2, typical_day_4 2, typical_5_10 3, typical_11_14 2, typical_gt_14 -1; rapid_lt_48h 2, rapid_gt_48h -1) + nadir (le_20 -2, gt_20 2) + thrombosis select at most one (none 0; typical_new_ge_4d 3, typical_progression 2; rapid_new 3, rapid_progression 2) + skin_necrosis 3 + systemic_reaction 2 + bleeding -1 + other causes select all (chronic_thrombocytopenia -1, new_drug_thrombocytopenia -2, severe_infection -2, overt_dic -2, intra_arterial_device -2, cpb_96h -1, no_other_cause 3 mutually exclusive with other causes); Cuker 2010; range -16 to 19; cutoff 2 was 100% sensitive / 60% specific vs expert panel; cutoff 5 was 86% sensitive / 88% specific",
                "max_score": 19,
                "score": 14,
                "score_ge_2": true,
                "score_ge_5": true
              },
              {
                "citation": {
                  "authors": "Cuker A, Arepally G, Crowther MA, Rice L, Datko F, Hook K, Propert KJ, Kuter DJ, Ortel TL, Konkle BA, Cines DB",
                  "doi": "10.1111/j.1538-7836.2010.04059.x",
                  "id": "cuker-2010",
                  "pmid": "20854372",
                  "source": "J Thromb Haemost. 2010;8(12):2642-2650",
                  "title": "The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion"
                },
                "components": [
                  {
                    "factor": "magnitude",
                    "points": 3,
                    "present": true,
                    "value": "gt_50"
                  },
                  {
                    "factor": "timing",
                    "points": 3,
                    "present": true,
                    "value": "typical_5_10"
                  },
                  {
                    "factor": "nadir",
                    "points": 2,
                    "present": true,
                    "value": "gt_20"
                  },
                  {
                    "factor": "thrombosis",
                    "points": 3,
                    "present": true,
                    "value": "typical_new_ge_4d"
                  },
                  {
                    "factor": "skin_necrosis",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "systemic_reaction",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "bleeding",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "chronic_thrombocytopenia",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "new_drug_thrombocytopenia",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "severe_infection",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "overt_dic",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "intra_arterial_device",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "cpb_96h",
                    "points": 0,
                    "present": false
                  },
                  {
                    "factor": "no_other_cause",
                    "points": 3,
                    "present": true
                  }
                ],
                "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                "formula": "hep",
                "formula_expression": "HEP = magnitude (lt_30 -1, 30_to_50 1, gt_50 3) + timing (typical_lt_4 -2, typical_day_4 2, typical_5_10 3, typical_11_14 2, typical_gt_14 -1; rapid_lt_48h 2, rapid_gt_48h -1) + nadir (le_20 -2, gt_20 2) + thrombosis select at most one (none 0; typical_new_ge_4d 3, typical_progression 2; rapid_new 3, rapid_progression 2) + skin_necrosis 3 + systemic_reaction 2 + bleeding -1 + other causes select all (chronic_thrombocytopenia -1, new_drug_thrombocytopenia -2, severe_infection -2, overt_dic -2, intra_arterial_device -2, cpb_96h -1, no_other_cause 3 mutually exclusive with other causes); Cuker 2010; range -16 to 19; cutoff 2 was 100% sensitive / 60% specific vs expert panel; cutoff 5 was 86% sensitive / 88% specific",
                "max_score": 19,
                "score": 14,
                "score_ge_2": true,
                "score_ge_5": true
              }
            ],
            "path": "/api/calc/hep"
          },
          "type": "json"
        }
      },
      "schema": {
        "$schema": "https://json-schema.org/draft/2020-12/schema",
        "properties": {
          "input": {
            "additionalProperties": false,
            "properties": {
              "body": {
                "additionalProperties": false,
                "properties": {
                  "items": {
                    "items": {
                      "properties": {
                        "bleeding": {
                          "description": "Presence of bleeding, petechiae, or extensive bruising (Cuker 2010). true scores -1; false scores 0.",
                          "type": "boolean"
                        },
                        "chronic_thrombocytopenia": {
                          "description": "Presence of a chronic thrombocytopenic disorder (Cuker 2010 other causes; select all that apply). true scores -1. Mutually exclusive with no_other_cause true.",
                          "type": "boolean"
                        },
                        "cpb_96h": {
                          "description": "Cardiopulmonary bypass within the previous 96 hours (Cuker 2010). true scores -1. Mutually exclusive with no_other_cause true.",
                          "type": "boolean"
                        },
                        "intra_arterial_device": {
                          "description": "Indwelling intra-arterial device (Cuker 2010 examples: IABP, VAD, ECMO). true scores -2. Mutually exclusive with no_other_cause true.",
                          "type": "boolean"
                        },
                        "magnitude": {
                          "description": "Caller-assigned Cuker 2010 magnitude of platelet fall (peak to nadir since heparin exposure). lt_30 (<30%) scores -1; 30_to_50 (30-50%) scores 1; gt_50 (>50%) scores 3. magent does not grade platelet counts.",
                          "type": "string"
                        },
                        "nadir": {
                          "description": "Caller-assigned Cuker 2010 nadir platelet count. le_20 (≤20 ×10^9/L) scores -2; gt_20 (>20 ×10^9/L) scores 2. magent does not take a raw platelet count.",
                          "type": "string"
                        },
                        "new_drug_thrombocytopenia": {
                          "description": "Newly initiated non-heparin medication known to cause thrombocytopenia (Cuker 2010). true scores -2. Mutually exclusive with no_other_cause true.",
                          "type": "boolean"
                        },
                        "no_other_cause": {
                          "description": "No other apparent cause of thrombocytopenia (Cuker 2010). true scores 3. Must be false if any other-cause flag is true.",
                          "type": "boolean"
                        },
                        "overt_dic": {
                          "description": "Overt DIC as assigned by the caller (Cuker 2010: fibrinogen <100 mg/dL and D-dimer >5.0 μg/mL). true scores -2. magent does not assay fibrinogen or D-dimer. Mutually exclusive with no_other_cause true.",
                          "type": "boolean"
                        },
                        "severe_infection": {
                          "description": "Severe infection as an other cause of thrombocytopenia (Cuker 2010). true scores -2. Mutually exclusive with no_other_cause true.",
                          "type": "boolean"
                        },
                        "skin_necrosis": {
                          "description": "Skin necrosis at subcutaneous heparin injection sites (Cuker 2010). true scores 3; false scores 0. magent does not examine the skin.",
                          "type": "boolean"
                        },
                        "systemic_reaction": {
                          "description": "Acute systemic reaction after intravenous heparin bolus (Cuker 2010). true scores 2; false scores 0.",
                          "type": "boolean"
                        },
                        "thrombosis": {
                          "description": "Caller-assigned Cuker 2010 thrombosis (select at most one). none scores 0. Typical-onset: typical_new_ge_4d (new VTE or ATE ≥4 days after heparin) 3; typical_progression (progression of preexisting VTE or ATE while receiving heparin) 2. Rapid-onset: rapid_new (new VTE or ATE after heparin) 3; rapid_progression 2.",
                          "type": "string"
                        },
                        "timing": {
                          "description": "Caller-assigned Cuker 2010 timing. Typical-onset: typical_lt_4 (fall begins <4 days) -2; typical_day_4 (day 4) 2; typical_5_10 (days 5-10) 3; typical_11_14 (days 11-14) 2; typical_gt_14 (>14 days) -1. Rapid-onset after re-exposure within 100 days: rapid_lt_48h (<48 h) 2; rapid_gt_48h (>48 h) -1. magent does not infer day of onset.",
                          "type": "string"
                        }
                      },
                      "required": [
                        "magnitude",
                        "timing",
                        "nadir",
                        "thrombosis",
                        "skin_necrosis",
                        "systemic_reaction",
                        "bleeding",
                        "chronic_thrombocytopenia",
                        "new_drug_thrombocytopenia",
                        "severe_infection",
                        "overt_dic",
                        "intra_arterial_device",
                        "cpb_96h",
                        "no_other_cause"
                      ],
                      "type": "object"
                    },
                    "maxItems": 25,
                    "minItems": 1,
                    "type": "array"
                  }
                },
                "required": [
                  "items"
                ],
                "type": "object"
              },
              "headers": {
                "additionalProperties": {
                  "type": "string"
                },
                "type": "object"
              },
              "method": {
                "const": "POST",
                "type": "string"
              },
              "type": {
                "const": "http",
                "type": "string"
              }
            },
            "required": [
              "type",
              "method"
            ],
            "type": "object"
          },
          "output": {
            "properties": {
              "example": {
                "type": "object"
              },
              "type": {
                "type": "string"
              }
            },
            "required": [
              "type"
            ],
            "type": "object"
          }
        },
        "required": [
          "input"
        ],
        "type": "object"
      }
    }
  },
  "tags": [
    "hep",
    "hit",
    "heparin",
    "thrombocytopenia",
    "calculator",
    "bazaar"
  ],
  "sourceHost": "api.magentlab.com",
  "lastUpdated": "2026-10-12T14:58:59.495Z",
  "quality": {
    "calls30d": 4,
    "uniquePayers30d": 2,
    "lastCalledAt": "2026-10-12T14:58:59.346Z"
  },
  "metadata": {
    "serviceName": "magent",
    "extensions": {
      "bazaar": {
        "info": {
          "iconUrl": "https://api.magentlab.com/favicon.ico",
          "input": {
            "body": {
              "items": [
                {
                  "bleeding": false,
                  "chronic_thrombocytopenia": false,
                  "cpb_96h": false,
                  "intra_arterial_device": false,
                  "magnitude": "gt_50",
                  "nadir": "gt_20",
                  "new_drug_thrombocytopenia": false,
                  "no_other_cause": true,
                  "overt_dic": false,
                  "severe_infection": false,
                  "skin_necrosis": false,
                  "systemic_reaction": false,
                  "thrombosis": "typical_new_ge_4d",
                  "timing": "typical_5_10"
                },
                {
                  "bleeding": false,
                  "chronic_thrombocytopenia": false,
                  "cpb_96h": false,
                  "intra_arterial_device": false,
                  "magnitude": "gt_50",
                  "nadir": "gt_20",
                  "new_drug_thrombocytopenia": false,
                  "no_other_cause": true,
                  "overt_dic": false,
                  "severe_infection": false,
                  "skin_necrosis": false,
                  "systemic_reaction": false,
                  "thrombosis": "typical_new_ge_4d",
                  "timing": "typical_5_10"
                }
              ]
            },
            "method": "POST",
            "type": "http"
          },
          "output": {
            "example": {
              "count": 2,
              "items": [
                {
                  "citation": {
                    "authors": "Cuker A, Arepally G, Crowther MA, Rice L, Datko F, Hook K, Propert KJ, Kuter DJ, Ortel TL, Konkle BA, Cines DB",
                    "doi": "10.1111/j.1538-7836.2010.04059.x",
                    "id": "cuker-2010",
                    "pmid": "20854372",
                    "source": "J Thromb Haemost. 2010;8(12):2642-2650",
                    "title": "The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion"
                  },
                  "components": [
                    {
                      "factor": "magnitude",
                      "points": 3,
                      "present": true,
                      "value": "gt_50"
                    },
                    {
                      "factor": "timing",
                      "points": 3,
                      "present": true,
                      "value": "typical_5_10"
                    },
                    {
                      "factor": "nadir",
                      "points": 2,
                      "present": true,
                      "value": "gt_20"
                    },
                    {
                      "factor": "thrombosis",
                      "points": 3,
                      "present": true,
                      "value": "typical_new_ge_4d"
                    },
                    {
                      "factor": "skin_necrosis",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "systemic_reaction",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "bleeding",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "chronic_thrombocytopenia",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "new_drug_thrombocytopenia",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "severe_infection",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "overt_dic",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "intra_arterial_device",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "cpb_96h",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "no_other_cause",
                      "points": 3,
                      "present": true
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "hep",
                  "formula_expression": "HEP = magnitude (lt_30 -1, 30_to_50 1, gt_50 3) + timing (typical_lt_4 -2, typical_day_4 2, typical_5_10 3, typical_11_14 2, typical_gt_14 -1; rapid_lt_48h 2, rapid_gt_48h -1) + nadir (le_20 -2, gt_20 2) + thrombosis select at most one (none 0; typical_new_ge_4d 3, typical_progression 2; rapid_new 3, rapid_progression 2) + skin_necrosis 3 + systemic_reaction 2 + bleeding -1 + other causes select all (chronic_thrombocytopenia -1, new_drug_thrombocytopenia -2, severe_infection -2, overt_dic -2, intra_arterial_device -2, cpb_96h -1, no_other_cause 3 mutually exclusive with other causes); Cuker 2010; range -16 to 19; cutoff 2 was 100% sensitive / 60% specific vs expert panel; cutoff 5 was 86% sensitive / 88% specific",
                  "max_score": 19,
                  "score": 14,
                  "score_ge_2": true,
                  "score_ge_5": true
                },
                {
                  "citation": {
                    "authors": "Cuker A, Arepally G, Crowther MA, Rice L, Datko F, Hook K, Propert KJ, Kuter DJ, Ortel TL, Konkle BA, Cines DB",
                    "doi": "10.1111/j.1538-7836.2010.04059.x",
                    "id": "cuker-2010",
                    "pmid": "20854372",
                    "source": "J Thromb Haemost. 2010;8(12):2642-2650",
                    "title": "The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion"
                  },
                  "components": [
                    {
                      "factor": "magnitude",
                      "points": 3,
                      "present": true,
                      "value": "gt_50"
                    },
                    {
                      "factor": "timing",
                      "points": 3,
                      "present": true,
                      "value": "typical_5_10"
                    },
                    {
                      "factor": "nadir",
                      "points": 2,
                      "present": true,
                      "value": "gt_20"
                    },
                    {
                      "factor": "thrombosis",
                      "points": 3,
                      "present": true,
                      "value": "typical_new_ge_4d"
                    },
                    {
                      "factor": "skin_necrosis",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "systemic_reaction",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "bleeding",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "chronic_thrombocytopenia",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "new_drug_thrombocytopenia",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "severe_infection",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "overt_dic",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "intra_arterial_device",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "cpb_96h",
                      "points": 0,
                      "present": false
                    },
                    {
                      "factor": "no_other_cause",
                      "points": 3,
                      "present": true
                    }
                  ],
                  "disclaimer": "Not a medical device. Deterministic published-formula or published-code output for autonomous agents. A licensed clinician remains responsible for patient care and billing submissions.",
                  "formula": "hep",
                  "formula_expression": "HEP = magnitude (lt_30 -1, 30_to_50 1, gt_50 3) + timing (typical_lt_4 -2, typical_day_4 2, typical_5_10 3, typical_11_14 2, typical_gt_14 -1; rapid_lt_48h 2, rapid_gt_48h -1) + nadir (le_20 -2, gt_20 2) + thrombosis select at most one (none 0; typical_new_ge_4d 3, typical_progression 2; rapid_new 3, rapid_progression 2) + skin_necrosis 3 + systemic_reaction 2 + bleeding -1 + other causes select all (chronic_thrombocytopenia -1, new_drug_thrombocytopenia -2, severe_infection -2, overt_dic -2, intra_arterial_device -2, cpb_96h -1, no_other_cause 3 mutually exclusive with other causes); Cuker 2010; range -16 to 19; cutoff 2 was 100% sensitive / 60% specific vs expert panel; cutoff 5 was 86% sensitive / 88% specific",
                  "max_score": 19,
                  "score": 14,
                  "score_ge_2": true,
                  "score_ge_5": true
                }
              ],
              "path": "/api/calc/hep"
            },
            "type": "json"
          }
        },
        "schema": {
          "$schema": "https://json-schema.org/draft/2020-12/schema",
          "properties": {
            "input": {
              "additionalProperties": false,
              "properties": {
                "body": {
                  "additionalProperties": false,
                  "properties": {
                    "items": {
                      "items": {
                        "properties": {
                          "bleeding": {
                            "description": "Presence of bleeding, petechiae, or extensive bruising (Cuker 2010). true scores -1; false scores 0.",
                            "type": "boolean"
                          },
                          "chronic_thrombocytopenia": {
                            "description": "Presence of a chronic thrombocytopenic disorder (Cuker 2010 other causes; select all that apply). true scores -1. Mutually exclusive with no_other_cause true.",
                            "type": "boolean"
                          },
                          "cpb_96h": {
                            "description": "Cardiopulmonary bypass within the previous 96 hours (Cuker 2010). true scores -1. Mutually exclusive with no_other_cause true.",
                            "type": "boolean"
                          },
                          "intra_arterial_device": {
                            "description": "Indwelling intra-arterial device (Cuker 2010 examples: IABP, VAD, ECMO). true scores -2. Mutually exclusive with no_other_cause true.",
                            "type": "boolean"
                          },
                          "magnitude": {
                            "description": "Caller-assigned Cuker 2010 magnitude of platelet fall (peak to nadir since heparin exposure). lt_30 (<30%) scores -1; 30_to_50 (30-50%) scores 1; gt_50 (>50%) scores 3. magent does not grade platelet counts.",
                            "type": "string"
                          },
                          "nadir": {
                            "description": "Caller-assigned Cuker 2010 nadir platelet count. le_20 (≤20 ×10^9/L) scores -2; gt_20 (>20 ×10^9/L) scores 2. magent does not take a raw platelet count.",
                            "type": "string"
                          },
                          "new_drug_thrombocytopenia": {
                            "description": "Newly initiated non-heparin medication known to cause thrombocytopenia (Cuker 2010). true scores -2. Mutually exclusive with no_other_cause true.",
                            "type": "boolean"
                          },
                          "no_other_cause": {
                            "description": "No other apparent cause of thrombocytopenia (Cuker 2010). true scores 3. Must be false if any other-cause flag is true.",
                            "type": "boolean"
                          },
                          "overt_dic": {
                            "description": "Overt DIC as assigned by the caller (Cuker 2010: fibrinogen <100 mg/dL and D-dimer >5.0 μg/mL). true scores -2. magent does not assay fibrinogen or D-dimer. Mutually exclusive with no_other_cause true.",
                            "type": "boolean"
                          },
                          "severe_infection": {
                            "description": "Severe infection as an other cause of thrombocytopenia (Cuker 2010). true scores -2. Mutually exclusive with no_other_cause true.",
                            "type": "boolean"
                          },
                          "skin_necrosis": {
                            "description": "Skin necrosis at subcutaneous heparin injection sites (Cuker 2010). true scores 3; false scores 0. magent does not examine the skin.",
                            "type": "boolean"
                          },
                          "systemic_reaction": {
                            "description": "Acute systemic reaction after intravenous heparin bolus (Cuker 2010). true scores 2; false scores 0.",
                            "type": "boolean"
                          },
                          "thrombosis": {
                            "description": "Caller-assigned Cuker 2010 thrombosis (select at most one). none scores 0. Typical-onset: typical_new_ge_4d (new VTE or ATE ≥4 days after heparin) 3; typical_progression (progression of preexisting VTE or ATE while receiving heparin) 2. Rapid-onset: rapid_new (new VTE or ATE after heparin) 3; rapid_progression 2.",
                            "type": "string"
                          },
                          "timing": {
                            "description": "Caller-assigned Cuker 2010 timing. Typical-onset: typical_lt_4 (fall begins <4 days) -2; typical_day_4 (day 4) 2; typical_5_10 (days 5-10) 3; typical_11_14 (days 11-14) 2; typical_gt_14 (>14 days) -1. Rapid-onset after re-exposure within 100 days: rapid_lt_48h (<48 h) 2; rapid_gt_48h (>48 h) -1. magent does not infer day of onset.",
                            "type": "string"
                          }
                        },
                        "required": [
                          "magnitude",
                          "timing",
                          "nadir",
                          "thrombosis",
                          "skin_necrosis",
                          "systemic_reaction",
                          "bleeding",
                          "chronic_thrombocytopenia",
                          "new_drug_thrombocytopenia",
                          "severe_infection",
                          "overt_dic",
                          "intra_arterial_device",
                          "cpb_96h",
                          "no_other_cause"
                        ],
                        "type": "object"
                      },
                      "maxItems": 25,
                      "minItems": 1,
                      "type": "array"
                    }
                  },
                  "required": [
                    "items"
                  ],
                  "type": "object"
                },
                "headers": {
                  "additionalProperties": {
                    "type": "string"
                  },
                  "type": "object"
                },
                "method": {
                  "const": "POST",
                  "type": "string"
                },
                "type": {
                  "const": "http",
                  "type": "string"
                }
              },
              "required": [
                "type",
                "method"
              ],
              "type": "object"
            },
            "output": {
              "properties": {
                "example": {
                  "type": "object"
                },
                "type": {
                  "type": "string"
                }
              },
              "required": [
                "type"
              ],
              "type": "object"
            }
          },
          "required": [
            "input"
          ],
          "type": "object"
        }
      }
    }
  },
  "liveness": {
    "reliability": null
  },
  "verified": false,
  "featured": false,
  "provider": {
    "host": "api.magentlab.com",
    "manifest_name": "api.magentlab.com",
    "source": "cdp-mirror",
    "source_manifest_url": "https://api.cdp.coinbase.com/platform/v2/x402/discovery/resources",
    "submitted_at": "2026-10-14T01:15:01.050Z"
  },
  "exampleResponse": {
    "example": {},
    "type": "string"
  }
}